10.07.2015 Views

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareFunctional descriptionStaircase timer functionThe Staircase timer function that can be parameterized separately can be used for implementing timecontrolledstaircase lighting or functionally similar applications. The Staircase timer function must havebeen enabled in the "Groups - [x] group name – Staircase timer function" parameter node to make therequired communication objects and parameters visible. The Staircase timer function can beparameterized only for the groups 1 ... 16.The Staircase timer function is controlled via the “Start/Stop Staircase timer function” communicationobject and depends on the “Switching” object of the group (cf. figure 24). This permits a 'paralleloperation' of time and normal control, with always the last command being executed.A telegram to the "Switching" object during an active Staircase timer function ends the staircaselighting time prematurely and sets the switching status according to the object value (time delays takeninto account). Similarly, the switching state of the "Switching" object can be overridden by a Staircasetimer function.In combination with a disable function a time-independent permanent lighting function can also be setup (cf. "Disable function").The Staircase timer function can be extended by a pre-warning function. The brightness of the <strong>DALI</strong>group can be reduced during the pre-warning. In acc. with DIN 18015-2, the pre-warning function isdesigned to warn anyone present in the staircase that the lights will go out shortly.Object"Disable" / "Forced-control"Object"staircase timerfunction start/stop"Staircase timerfunction(timing)Object"Central function"*Polarity ofcentral object*Object"Switching"*Time functions*Soft-ON / OFF*additional functionBehaviour- bus voltage failure- bus voltage return- ETS programmingBlinking*GroupObject"Dimming"lowerhigherScene priorityObject"Brightness value"Dimming speed /Dimming behaviourautomaticshutoff function*Object"Extension unit"*Scenecontrol*recallstoring **Object"Brightness valuefeedback"Object"Switchingfeedback"Verzögerung nachBusspannungswiederkehr*zyklisches Senden** = optional parameterization** = Basically, no new scene value willbe stored if a disable or forced-controlposition is active!Fig. 24: Functional diagram of the Staircase timer functionSeite 74 von 130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!