<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareFunctional descriptionSetting the response to bus voltage failureThe “Response to bus voltage failure” parameter is created separately for each group in the “Groups -[x] group name" parameter node (x = group number 1...32).• Set the parameter to "No change".Following a bus voltage failure, the <strong>DALI</strong> devices of a group will not react and keep the currentbrightness value or remain switched off.• Set the parameter to "Switch-off".In case of bus voltage failure the group will be switched off.• Set the parameter to "Brightness value". Select the required brightness value in the selection field.The group will be set to the brightness value specified in the selection field. The adjustable valuemust be within the limits of the parameterized maximum and minimum brightness.• The <strong>DALI</strong> devices assigned to the group will behave according to the parameterized response to busvoltage failure ("SystemFailureLevel") even in case of a voltage failure in the <strong>DALI</strong> line (e.g. shortcircuit,cable break, mains voltage failure only at the <strong>DALI</strong> <strong>Gateway</strong>).• The current states of the forced-control positions will also be stored in case of bus or mains voltagefailure so they can be resumed, if needed, after the return of bus and mains voltage (depends on theparameterization of the forced-control position functions).• A bus voltage failure will always cause the deletion of active disable or forced-control positionfunctions rendering them inactive.Setting the response to bus voltage returnThe “Response to bus voltage return” parameter is created separately for each group in the “Groups -[x] group name" parameter node (x = group number 1...32). The parameter also defines the behaviourafter mains voltage return.• Set the parameter to "No change".Following a bus/ mains voltage failure, the <strong>DALI</strong> devices of a group will show no response and keepthe current brightness value or remain switched off.• Set the parameter to "Switch-off".The group will be switched off in case of bus/mains voltage failure.• Set the parameter to "Brightness value as prior to bus voltage failure".After bus/ mains voltage return, the brightness value that was internally stored last prior to the bus/mains voltage failure is resumed.• Set the parameter to "Brightness value". Select the required brightness value in the selection field.The group will be set to the brightness value specified in the selection field. The adjustable valuemust be within the limits of the parameterized maximum and minimum brightness.Seite 51 von 130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!