10.07.2015 Views

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

hager TX216 KNX/EIB DALI-Gateway - UTU

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>hager</strong>"<strong>DALI</strong> <strong>Gateway</strong> C00Cx2" softwareFunctional descriptionCreated scenes can be deleted at any time by selecting a scene and executing the “Delete” commandin the context menu.Each scene can be assigned a name. The scene must be selected and opened via the “Rename”command in the context menu. It is recommended to assign each scene a unique name (e.g. “Lecturedesk”, “Meeting large”, etc.). The name may not exceed 28 characters and may include alphanumericalas well as special characters.For better orientation and differentiation of the individual scenes, the name will only be shown in theplug-in. A scene name can also be edited in the parameter configuration of a scene via the “Name”parameter.The scene brightness values are recalled or stored via a separate scene extension object affectingseveral channels by means of extension telegrams. The data point type of the extension object makesit possible to control each scene separately via their fixed scene number (1...16). Optionally, eachscene recall can also be delayed.A scene recall overrides a set brightness value via the “Brightness value” object as well as a switchingor dimming operation via the “Switching”, “Switching central function” and “Dimming” objects of agroup. A Staircase timer function will also be overridden by a scene recall. The priority of the scenefunction to the disable or forced-control position functions of a group can be parameterized for eachscene. That makes it possible to have a scene recall override a disable or forced-control positionfunction. Alternatively, a scene can have a lower priority preventing disable or forced-control positionfunctions to be overridden by a scene recall.A function overridden by a scene recall will be re-executed if the function has been updated via the<strong>KNX</strong>/<strong>EIB</strong>.Object"Disable" / "Forced-control"Object"staircase timerfunction start/stop"* Staircase timerfunction(timing)*Object"Central function"*Polarity ofcentral object*Object"Switching"*Time functions*Soft-ON / OFF*additional functionBehaviour- bus voltage failure- bus voltage return- ETS programmingBlinking*GroupObject"Dimming"lowerhigherScene priorityObject"Brightness value"Dimming speed /Dimming behaviourautomaticshutoff function*Object"Extension unit"Scenecontrolrecallstoring **Object"Brightness valuefeedback"Object"Switchingfeedback"Verzögerung nachBusspannungswiederkehr*zyklisches Senden** = optional parameterization** = Basically, no new scene value willbe stored if a disable or forced-controlposition is active!Fig. 32: Functional diagram of the scene functionSeite 81 von 130

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!