Ch. 17 – Using Other Mac Imaging Application in <strong>Basic</strong> Mode<strong>Manual</strong> Exposure OptionsExposure Time(s)Use the slider-bar to specify an exposure time (or times) between .04 ms <strong>and</strong> 526.746 sec.When you specify an exposure time, the camera skips the automated exposure sequence that takes placewhen you open the live image view – i.e., the 3rd Party interface. This is very useful in cases whereexposure times are lengthy, as with fluorescence samples.GainEnter the precise gain that the camera will use <strong>for</strong> an image capture. Use the slider-bar to select one of thegain options: 1, 2, 4, 8, or 16. The gain value displays to the right of the slider-bar. Refer to the “Auto-Gain Limit ” <strong>and</strong> “Gain” sections of Ch. 5 – Preparing to Take a Picture <strong>for</strong> details on gain <strong>and</strong> exposure.GammaThe manual Gamma adjustment is identical to the auto Gamma adjustment (see above.)White BalanceWhite balance is the ratio of red, green, <strong>and</strong> blue gains necessary to achieve the proper color rendition <strong>for</strong>an image. Many factors impact the coloration of an image capture, including lamp voltage, the colorationof the glass used in the slide, <strong>and</strong> the coloration of the glass used in the lenses of the microscope’sobjectives. To minimize the impact of these factors, use the White Balance feature. When you per<strong>for</strong>m awhite balance calculation, <strong>SPOT</strong> samples the color of the light from your light source after it has passedthrough the slide <strong>and</strong> the objective, <strong>and</strong> then calculates the red, green, <strong>and</strong> blue gains needed to produceimages where the white areas are white <strong>and</strong> the color areas are true.You should per<strong>for</strong>m a new white balance calculation when:• Starting a new image capture session.• Changing the lamp voltage.• Switching to a different objective on the microscope.To per<strong>for</strong>m a white balance, follow these steps:1. Set the illumination <strong>and</strong> the objective that you will use <strong>for</strong> the image capture.2. If you have not done so, select your Image Type (see above). Each Image Type has its own set ofwhite balance values. Any white balance values that you compute <strong>for</strong> an image type remain linked tothat image type until you compute new values. When selecting a new image type, remember that youwill be using the white balance values linked to that image type.3. Click on the White Balance button.4. Show the camera a sample of white light. This step varies according to microscopy technique <strong>and</strong>Image Type (sample), as shown in the table below:306 User Guide to the <strong>SPOT</strong> <strong>Insight</strong> Camera

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!