12.07.2015 Views

SPOT 4.1 Basic and Advanced Software Manual for SPOT Insight ...

SPOT 4.1 Basic and Advanced Software Manual for SPOT Insight ...

SPOT 4.1 Basic and Advanced Software Manual for SPOT Insight ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Ch. 4 – <strong>Advanced</strong> Program ModeNote: In the case above, if you were to use a comm<strong>and</strong> in decimal, you would need to add a zero (0)in front of the comm<strong>and</strong> code 64 – (ex. \064). The comm<strong>and</strong> string \ddd requires 3 digits.Setting a Response Comm<strong>and</strong> - You may elect to receive a response when the <strong>SPOT</strong> program has sent thecomm<strong>and</strong>, <strong>and</strong> the external device has completed that comm<strong>and</strong>. Click on the Reponse String checkbox<strong>and</strong> type in the appropriate response comm<strong>and</strong>. This response comm<strong>and</strong> string will also be found, ifavailable, in the external device documentation.Using Variables - In the comm<strong>and</strong> string, you may insert variables. The variables will be exp<strong>and</strong>ed at thetime that the comm<strong>and</strong> is sent to the device. If you insert a "RunTimeText" variable, the user will beprompted, with your supplied prompt text, at the time the comm<strong>and</strong> is sent, <strong>and</strong> the user's response will beinserted into the comm<strong>and</strong> string at the point where the variable appears. The "TextVar" <strong>and</strong> "NumVar"variables may be useful when the comm<strong>and</strong> is used from within a macro (see Chapter 13 – MacroScripting).Using Timeouts - You may also select a time limit between the time that the comm<strong>and</strong> is sent by <strong>SPOT</strong><strong>and</strong> the time it takes <strong>for</strong> the comm<strong>and</strong> to be received <strong>and</strong> the action of the function is completed. This canbe h<strong>and</strong>y in letting you know that there is a communication problem between the computer <strong>and</strong> the externaldevice, when you expect an action to take place within a prescribed length of time.Testing the Peripheral Device Comm<strong>and</strong> - You may test the comm<strong>and</strong> immediately by selecting the Testbutton. If you have selected a timeout duration, a response window will let you know if the comm<strong>and</strong> hasnot been received <strong>and</strong> carried out within the prescribed length of time.Note: Make sure your external device is connected properly to the computer <strong>and</strong> that it is turned onbe<strong>for</strong>e considering other potential communication problems..Modifying <strong>and</strong> Deleting the Peripheral Device Comm<strong>and</strong> – Once you have created a comm<strong>and</strong>, you canmodify its parameters or delete it. Select the comm<strong>and</strong> from the Peripheral Device Window <strong>and</strong> push themodify or delete button78 User Guide to the <strong>SPOT</strong> <strong>Insight</strong> Camera

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!