Troubleshooting • Resolving Problems •• Disabling and Enabling a SocketDisabling and Enabling a SocketIf a single socket produces an excessive number of errors during<strong>RoadRunner</strong> operation, it is automatically disabled to improve throughputand reduce the likelihood of rejecting good devices due to a worn or dirtysocket. If the socket is known to be good, then it may be re-enabled by performingthe following:NOTE: Before enabling a socket that has been automatically disabled,be absolutely sure that it is not damaged in some way.Repeated failures on a single socket usually indicate socket failureor damage of some sort, even if it is not readily apparent.If no damage is suspected or visible ensure that there are no devicesin the socket before enabling.1. Press the Pause button on the Keypad if a job is currently running.2. Press the Menu button until Job is displayed.3. Press the Up Arrow or Down Arrow buttons until Socket is displayed.Press the Select button.4. Press the Up Arrow or Down Arrow buttons until the disabled socket ishighlighted. Press the Select button.5. Press the Up Arrow button to change the state of the socket from Disabledto Enabled.6<strong>Data</strong> I/O • ProLINE-<strong>RoadRunner</strong> Owner’s <strong>Manual</strong> • 096-0240 [updated Mar2010] 6—3