Installation • Making the Necessary Connections •• Pneumatic Input RequirementsCAUTION: Oil, excessive moisture, or poorly filtered air willobstruct <strong>RoadRunner</strong>’s internal air paths, affect system performance,and void the warranty related to air system failure. If oil orexcessive moisture is detected, contact your local <strong>Data</strong> I/Oapproved service representative immediately.2Inlet TubeThe 6 mm diameter inlet tube assembly, supplied, has a quick-disconnect fittingthat pushes onto the <strong>RoadRunner</strong> air connector. Allow the collar tomove while you push the fitting onto the connector.To remove the inlet air assembly, slide the sleeve on the tube connector backand pull it off. The tube fitting has an automatic shut off and may beremoved without shutting off the air pressure.NOTE: If the compressor cannot maintain the correct air pressureand volume, the <strong>RoadRunner</strong> will not operate correctly.<strong>Data</strong> I/O • ProLINE-<strong>RoadRunner</strong> Owner’s <strong>Manual</strong> • 096-0240 [updated Mar2010] 2—27