Operation • Operator Functions •• Setting Up <strong>RoadRunner</strong> for a Programming JobOperator FunctionsChanging the PrecisorThe precisor assists in properly aligning each device before it is placed intothe programming socket. Each precisor is shaped to correspond with a specificdevice.NOTE: <strong>RoadRunner</strong> XLF Models do not use precisors.To change the precisor:1. Push the Emergency-Stop button.2. Lift off the Robotics Cover.3. Lift off the PNP head Cover.4. Being careful not to disturb the probe tips, pull the precisor plate downfrom the magnetized surface above. (We suggest grasping the ends witha thumb and finger and lowering one end away from the head at a time.)3Figure 3-5—Removing the Precisor [Siemens Model Shown]5. Install the new precisor. Make sure that the name on the precisor facesup and the small dowel pin holes near the precisor edges mate up withthe dowel pins on the PNP head. There should be no visible gapbetween the precisor and the PNP head.Figure 3-6—Identifying the New Precisor6. When you are finished, release the Emergency-Stop button.<strong>Data</strong> I/O • ProLINE-<strong>RoadRunner</strong> Owner’s <strong>Manual</strong> • 096-0240 [updated Mar2010] 3—7