30.07.2015 Views

RoadRunner Owner's Manual - Data I/O Corporation

RoadRunner Owner's Manual - Data I/O Corporation

RoadRunner Owner's Manual - Data I/O Corporation

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Troubleshooting • Error Messages •• Blue Lamp is OnLampColor. . .bluelamp is on. . .Error MessageError encountered readingfile.Errors encountered inSECTPROT.TXT file forjobField Update failed. OnboardFLASH is inunknown state.Incompatible boards inProgrammer.Incorrect Programmerboard configuration for Job.Invalid Job name.Invalid LCA file.Invalid parameter name infile:...Invalid parameter value infile:...Job card not present.Job in progress. End currentjob in order to proceed.Missing parameter in file:...Motor controller notresponding.No Adapter installed.ResolutionMake a new job card by recreating the job in TaskLink.Make a new job card by recreating the job in TaskLink.Programmer Module requires repair or replacement.Contact <strong>Data</strong> I/O Customer Service.Programmer Module requires repair or replacement.Contact <strong>Data</strong> I/O Customer Service.The Job parameters are not compatible with the Programmer. Checkthe Job parameters or Contact <strong>Data</strong> I/O Customer Service.Make a new job card by recreating the job in TaskLink.Reload the Job onto the card.Reload the Job onto the card using the current version of TaskLink.Reload the Job onto the card using the current version of TaskLink.Insert a card into the PCMCIA slot.Using the keypad, select End from the top level Job menu.• Reload the job.• Contact <strong>Data</strong> I/O Customer Service.Make sure Emergency Stop is not depressed.Install the socket adapter for the devices being programmed.No Job Selected.NVRAM Battery Failed.PNP motor controller notresponding.Programmer continuousover-current error.Programmer FPGA Failure.• Select a Job (Supervisor Mode).• Verify that the job card has a job written on it.Programmer Module requires repair or replacement.Contact <strong>Data</strong> I/O Customer Service.Make sure Emergency Stop is not depressed.No operator intervention required.Programmer Module requires repair or replacement.Contact <strong>Data</strong> I/O Customer Service.6. . .bluelamp is on. . .Programmer Shift ChainFailure.Contact <strong>Data</strong> I/O Customer Service.<strong>Data</strong> I/O • ProLINE-<strong>RoadRunner</strong> Owner’s <strong>Manual</strong> • 096-0240 [updated Mar2010] 6—11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!