INDEX > 4.Replacement Procedure > 4.3 Scanner Unit NKE-2254 (<strong>JMA</strong>-5322-7/9/6HS)<br />

4.3.3 Motor replacement (7BDRD0044A, 7BDRD0045A)<br />

[Required tools]<br />

• Single-ended wrench (width across flats 17 mm for<br />

M8 bolts)<br />

• Tools for removing the cover from the scanner unit (see Section 4.3.1, page 4-24)<br />

[Replacement procedure]<br />

1) Remove the cover on the left (port) side<br />

(see Section 4.3.1, page 4-24) and remove<br />

the cables connected to the motor driver<br />

circuit board.<br />

Remove the<br />

four bolts.<br />

Remove the<br />

two cables.<br />

2) Remove the hexagonal bolts (four M8 bolts)<br />

and remove the motor.<br />

Motor<br />

3) Remove the hexagonal bolts (four M8<br />

bolts) and remove the installation plate<br />

from the motor.<br />

Motor driver circuit board<br />

Remove the<br />

four bolts.<br />

4) Attach the installation plate to the<br />

replacement motor.<br />

Do not forget to tighten the hexagonal bolts<br />

to an appropriate torque (210 kgf-cm) so<br />

they are free of looseness.<br />

Motor<br />

Installation plate<br />

4-28