INDEX > 4.Replacement Procedure > 4.6 Display Unit : Radar Process Unit NDC-1417<br />

4) Remove the four screws holding the fan fixture,<br />

remove the fan connectors, and remove the fan<br />

fitting. (Use the Phillips screwdriver for 3 mm<br />

screws.)<br />

Remove<br />

Remove<br />

5) Remove the screw holding the metal fitting that<br />

protects the process unit circuit breaker. (Use the<br />

Phillips screwdriver for 2.6 mm screws.)<br />

Remove<br />

6) Remove the two screws holding the process unit<br />

circuit breaker, and remove the circuit breaker.<br />

(Use the Phillips screwdriver for 3 mm screws.)<br />

Remove<br />

7) Remove the five connectors connected to the<br />

radar process circuit.<br />

Remove<br />

4-74