INDEX > 4.Replacement Procedure > 4.5 Display Unit : LCD Monitor NWZ-173<br />

4.5.6 Blower Circuit replacement (CBP-173A)<br />

[Note]<br />

Do not touch the LCD screen directly with your fingers.<br />

Do not touch the AR filter directly with your fingers.<br />

Perform the replacement work on a soft cloth to avoid damage to the LCD screen and<br />

other parts.<br />

[Required tools]<br />

• A Phillips screwdriver for M4 screws、6mm 用<br />

• A pair of nippers<br />

[Replacement procedure]<br />

1) Follow the procedures provided in Section 4.5.2, page 4-60 to remove the LCD unit.<br />

2) Remove the two screws (M3).<br />

Remove<br />

3) Remove the cable and the fan.<br />

4) Install the fan in the reverse order of the<br />

removal.<br />

5) Follow the procedures provided in Section 4.5.2, page 4-60 to install the LCD unit.<br />

[Check points]<br />

1) After completing the replacement procedures, start the system to make sure that images<br />

are displayed properly.<br />

2) Turn the brightness knob to make sure the brightness can be changed between the<br />

minimum and the maximum levels.<br />

3) Check that no fan alarm comes on.<br />

4-68