09.03.2016 Views

JMA-5300MkIIsm

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INDEX > 4.Replacement Procedure > 4.6 Display Unit : Radar Process Unit NDC-1417<br />

9) Check the fuses of the new GYRO I/F circuit board.<br />

10) Reassemble the unit following the disassembly procedure in reverse.<br />

11) Turn on the system's power and set the true azimuth.<br />

[Check points]<br />

1) Check that no error message is displayed.<br />

2) Check that the true azimuth is correctly tracked. (In terms of the resolution and rotation<br />

direction.)<br />

4<br />

4.6.8 GYRO Interface Circuit Fuses replacement (MF51NR-0.5A)<br />

[Required tools]<br />

Flat screwdriver for 3 mm screws<br />

Phillips screwdriver for 3 mm screws<br />

[Replacement procedure]<br />

1) Remove the four screws at the top of the<br />

process unit cover and the three screws<br />

on each side to remove the process unit<br />

cover. (Use the Phillips screwdriver for 3<br />

mm screws.)<br />

4-83