JMA-5300MkIIsm
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
INDEX > 6.Troubleshooting > 6.2 Scanner Unit error messages<br />
[2] Problem location<br />
[2]-1 Scanner Unit installation cable<br />
• Check the installation cable of the Scanner Unit or the Scanner Unit.<br />
TB201 MTR+/MTR-<br />
TB203 +48V/+48VG、<br />
• Check the installation cable. (NKE-2103)<br />
[2]-2 T/R Control Circuit CMC-1205R in Scanner Unit (NKE-2254/1130)<br />
• Check that all the connectors for T/R Control Circuit CMC-1205R are inserted.<br />
TB101 MTR+/MTR-, J1103<br />
• T/R Control Circuit replacement (CMC-1205R). (NKE-2254, see section 4.2.10, page<br />
4-14)<br />
• T/R Control Circuit replacement (CMC-1205R). (NKE-1130, see section 4.3.8, page<br />
4-36)<br />
[2]-3 Power Supply Circuit CBD-1682A in Scanner Unit (NKE-2254/1130)<br />
• Check that each connector for Power Supply Circuit CBD-1682A is inserted.<br />
J3 1A/2A:DC48V, J1003<br />
• Power Supply Circuit replacement (CBD-1682A). (NKE-1130, see section 4.2.9,<br />
page 4-13)<br />
• Power Supply Circuit replacement (CBD-1682A). (NKE-2254, see section 4.3.7,<br />
page 4-35)<br />
[2]-4 Modulator Circuit CME-363 in the Scanner Unit (NKE-2103)<br />
• Check the insertion status of J201 and J205 in Modulator Circuit CME-363<br />
• Modulator Circuit replacement (CME-363). (see section 4.4.5, page 4-51)<br />
[2]-5 Receiver Unit NRG-610 in the Scanner Unit (NKE-2103)<br />
• Check the insertion status of J301 in I/F Amp Circuit CAE-529-1.<br />
• Receiver Unit replacement (NRG-610). (see section 4.4.7, page 4-53)<br />
[2]-6 Power Supply Circuit CBD-1783 (NKE-2103)<br />
• Check the insertion status of J1002 in Power Supply Circuit CBD-1783.<br />
• Power Supply Circuit replacement (CBD-1783). (see section 4.4.6, page 4-52)<br />
[2]-7 Internal cable for Scanner Unit<br />
• Check the internal cable. (NKE-2103)<br />
6-18