09.03.2016 Views

JMA-5300MkIIsm

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX > 4.Replacement Procedure > 4.2 Scanner Unit NKE-1130 (<strong>JMA</strong>-5332-12)<br />

3) Remove the cable connected to the relay filter<br />

circuit board and the four screws (M4) to replace<br />

the relay filter circuit board.<br />

Remove<br />

the screws.<br />

4) After replacing the relay filter circuit board,<br />

follow the disassembly procedure in the reverse<br />

order.<br />

Do not forget to tighten the screws and connect the<br />

cables.<br />

Relay filter circuit board<br />

[Check points]<br />

1) Turn on the radar power supply. After the countdown is completed, start emission and<br />

check that the radar image appears without error.<br />

4.2.12 Receiver Unit Replacement (NRG-229)<br />

[Required tools]<br />

• A Phillips screwdriver for 4 mm screws<br />

• A Phillips screwdriver for 5 mm screws<br />

• Tools for removing the cover from the scanner unit<br />

(see Section 4.2.1, page 4-2)<br />

[Replacement procedure]<br />

1) Remove the cover on the right (starboard)<br />

side (see Section 4.2.1, page 4-2). Remove<br />

the four screws (M5) to remove the metal<br />

fixture. Loosen the four screws (M4) to<br />

remove the driver unit (see Section 4.2.4,<br />

page 4-8).<br />

Remove the four screws.<br />

Driver unit<br />

Metal fixture<br />

Loosen the four screws.<br />

4-16