09.03.2016 Views

JMA-5300MkIIsm

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INDEX > 6.Troubleshooting > 6.5 Sample Problems : Internal Circuit<br />

6.5.6 "Scanner Rotating" message displayed, Scanner Unit does<br />

not stop when transmission stops<br />

[1] Content<br />

The scanner keeps rotating even when transmission is stops. The "Scanner<br />

Rotating" warning appears in yellow.<br />

[2] Problem location<br />

[2]-1 Setting<br />

• The unit is set to ICE CLASS Standby Mode. If this is not necessary, clear the<br />

setting (Refer to Section 6.5.6 of the instruction manual).<br />

6.5.7 Display unit layout shown on inter switch menu is mirror<br />

image of actual layout<br />

[1] Content<br />

It was not possible in the installation work to number the display units left to right<br />

from No. 1.<br />

6<br />

[2] Problem location<br />

[2]-1 Interswitch unit<br />

• Switch the terminal blocks on the Interswitch side.<br />

6.5.8 Displayed echo does not match distance / azimuth of actual<br />

ship<br />

[1] Content<br />

At close range, the displayed echo does not match the distance / azimuth of the<br />

actual ship.<br />

[2] Problem location<br />

[2]-1 CCRP setting error<br />

• Set the CCRP correctly (Refer to Section 7.1.9 of the instruction manual).<br />

6-45