Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX > 4.Replacement Procedure > 4.4 Scanner Unit NKE-2103 (<strong>JMA</strong>-5312-6/6HS)<br />

4.4.2 Magnetron replacement (MAF1565N)<br />

[Required tools]<br />

• A Phillips screwdriver for 4 mm screws<br />

• A shielded Phillips screwdriver for 5 mm screws<br />

• Tools for removing the cover from the scanner unit<br />

(see Section 4.4.1, page 4-46)<br />

[Replacement procedure]<br />

1) Open the upper cover (see Section 4.4.1, page 4-46),<br />

loosen the screws (four M4 screws), remove the<br />

transmitter-receiver unit cover, and remove the cables<br />

connected to the transmitter-receiver unit (ten cables).<br />

Slide the cover of the transmitter-receiver unit to remove<br />

it.<br />

Slide the cover.<br />

4<br />

Loosen the<br />

four screws.<br />

2) Loosen the bolts (five M5 bolts) and<br />

remove the transmitter-receiver unit.<br />

Slide the transmitter-receiver unit upward<br />

to remove it.<br />

Slide the unit.<br />

Tighten the<br />

five bolts.<br />