INDEX > 6.Troubleshooting > 6.6 External equipment<br />

6.6.3 Blurry image on the remote display<br />

[1] Content<br />

This problem occurs due to cable loss , long cables are used in connections or ,<br />

there is a mismatch with the input impedance on the remote display side.<br />

Correct operation has been confirmed using a 30 m cable to connect a JRC VDR,<br />

when using the CQD-1831 (VDR I/F kit) and a 3C-2V coaxial cable.<br />

[2] Problem location<br />

[2]-1 Cable type<br />

If it is necessary to transfer signals over a long distance, use a coaxial cable (such<br />

as 3C-2V).<br />

[2]-2 Cable length<br />

If it is necessary to transfer signals over a distance of 30 m or more, use a buffer<br />

amp (sold separately) in between the main unit and the remote display.<br />

[2]-3 Remote display<br />

The signal quality is also affected by the monitor used for the remote display. If<br />

the display is still distorted when a coaxial cable is used, the situation may be<br />

improved by using a buffer amp.<br />