09.03.2016 Views

JMA-5300MkIIsm

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

INDEX > 6.Troubleshooting > 6.3 Display Unit error messages<br />

6.3.10 ASIC1 to RADAR<br />

[1] Content<br />

There is a problem with the signal from the radar process circuit board in the<br />

Radar Process Unit of the display unit to the DSP circuit board.<br />

Normally, the system does not contain a DSP circuit board, so this message will<br />

not appear.<br />

If this error appears, this radar image cannot be displayed.<br />

[2] Problem location<br />

[2]-1 NCA-877WA/877A in Radar Process Unit<br />

• Check the installation connector of ARPA/ATA Process Circuit NCA-877WA/<br />

877A.<br />

• ARPA/ATA Process Circuit replacement (NCA-877WA/877A). (see section 4.6.5,<br />

page 4-78)<br />

[2]-2 Radar Process Circuit CDC-1332 in Radar Process Unit<br />

• Radar Process Circuit replacement (CDC-1332). (see section 4.6.3, page 4-73)<br />

6.3.11 AIS PROC (Data)<br />

[1] Content<br />

There is a problem with the signal from the AIS process circuit board in the Radar<br />

Process Unit of the display unit to the radar process circuit board.<br />

If this error appears, AIS information cannot be displayed.<br />

[2] Problem location<br />

[2]-1 NQA-2103 in Radar Process Unit<br />

• Check the installation status of AIS process circuit NQA-2103.<br />

• ARPA/ATA Process Circuit replacement (NCA-877WA/877A). (see section 4.6.5,<br />

page 4-78)<br />

[2]-2 Radar Process Circuit CDC-1332 in Radar Process Unit<br />

• Radar Process Circuit replacement (CDC-1332). (see section 4.6.3, page 4-73)<br />