INDEX > 4.Replacement Procedure > 4.5 Display Unit : LCD Monitor NWZ-173<br />

2) Remove the four screws (M3) and remove the<br />

mesh cover.<br />

3) Remove the cable and eight screws (M3), and<br />

remove the circuit board.<br />

Remove<br />

Remove<br />

4) Remove the fitting screws from the DVI and<br />

DSUB connectors and remove the shield plate.<br />

5) Install the circuit in the reverse order of the<br />

disassembly. There are two types of fitting<br />

screws, so be sure to use them appropriately<br />

(the shorter screw is for the DVI connector).<br />

6) Follow the procedures provided in Section<br />

4.5.2, page 4-60 to install the LCD unit.<br />

[Check points]<br />

1) After completing the replacement procedures, start the system to make sure that images<br />

are displayed properly.<br />