09.03.2016 Views

JMA-5300MkIIsm

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX > 4.Replacement Procedure > 4.6 Display Unit : Radar Process Unit NDC-1417<br />

4.6.5 ARPA/ATA Process Circuit replacement (NCA-877WA/877A)<br />

[Required tools]<br />

Phillips screwdriver for 3 mm screws<br />

[Replacement procedure]<br />

1) Refer to Section 4.6.2, page 4-70 and remove the terminal board.<br />

2) You will see the ARPA or ATA process<br />

circuit on the radar process circuit.<br />

3) Remove the four screws holding the ARPA or<br />

ATA process circuit in place, and lift out the<br />

ARPA or ATA process circuit vertically to<br />

replace it. (Use the Phillips screwdriver for 3 mm<br />

screws.)<br />

ARPA Process<br />

circuit<br />

Remove<br />

4) Reassemble the unit following the disassembly<br />

procedure in reverse.<br />

[Check points]<br />

Remove<br />

1) Check that the system starts up properly.<br />

2) Check that no error message appears.<br />

3) Refer to Section 5.2.7 II in the instruction manual to generate a false target, and check<br />

that you can acquire the target.<br />

4) Check that the numerical target data acquired is correctly displayed.<br />

4-78

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!