09.03.2016 Views

JMA-5300MkIIsm

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX > 4.Replacement Procedure > 4.2 Scanner Unit NKE-1130 (<strong>JMA</strong>-5332-12)<br />

4.2.6 Modulator Unit Fan replacement (7BFRD0002)<br />

[Required tools]<br />

• A Phillips screwdriver for 4 mm screws<br />

• Tools for removing the cover from the scanner unit<br />

(see Section 4.2.1, page 4-2)<br />

[Replacement procedure]<br />

1) Remove the cover on the left (port) side (see<br />

Section 4.2.1, page 4-2). Remove the modulator<br />

unit fan cable (connector P1112) from the relay<br />

connector.<br />

Remove the cable.<br />

Fan<br />

2) Remove the four screws (M4) to replace the fan.<br />

Fan<br />

3) After replacing the fan, assemble the unit in the<br />

reverse order of the disassembly procedure.<br />

Do not forget to tighten the screws and connect the<br />

cables.<br />

Remove<br />

the four<br />

screws.<br />

[Check points]<br />

1) Turn on the radar power supply. After the countdown is completed, start emission and<br />

check that the radar image appears without error. Check that no fan alarm comes up.<br />

4-10