INDEX > 4.Replacement Procedure > 4.2 Scanner Unit NKE-1130 (<strong>JMA</strong>-5332-12)<br />

4.2.8 Modulator Unit replacement (NMA-551-1)<br />

[Required tools]<br />

• A Phillips screwdriver for 4 mm screws<br />

• Tools for removing the cover from the scanner unit<br />

(see Section 4.2.1, page 4-2)<br />

[Replacement procedure]<br />

1) Remove the cover on the left (port) side (see Section 4.2.1, page 4-2) to remove all<br />

cables connected to the Modulator circuit board (CPA-264).<br />

2) Remove the magnetron (see Section 4.2.2, page 4-4).<br />

3) Remove the two screws (M4) holding the<br />

metal sheet and loosen the five screws<br />

(M5) holding the Modulator unit, to<br />

replace the Modulator unit.<br />

Remove<br />

4) Assemble the Modulator unit in the<br />

reverse order of the disassembly<br />

procedure.<br />

Loosen<br />

5) After replacing the Modulator unit,<br />

assemble the magnetron (see Section 4.2.2, page 4-4).<br />

Do not forget to tighten the screws and connect the cables.<br />

[Check points]<br />

1) Turn on the radar power supply. After the countdown is completed, start emission and<br />

check that the radar image appears without error.<br />

Transmit radar signals on a long range (48NM) and with the test menu open, also make sure<br />

the magnetron current is shown between the 6th and 9th calibration markings (see Section<br />

6.1.1, page 6-1).<br />