09.03.2016 Views

JMA-5300MkIIsm

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX > 4.Replacement Procedure > 4.3 Scanner Unit NKE-2254 (<strong>JMA</strong>-5322-7/9/6HS)<br />

4.3.4 Motor Control Power Circuit replacement (CBD-1779)<br />

[Required tools]<br />

• A Phillips screwdriver for 4 mm screws<br />

• Tools for removing the cover from the scanner<br />

unit(see Section 4.3.1, page 4-24)<br />

[Replacement procedure]<br />

1) Remove the cover on the left (port) side (see<br />

Section 4.3.1, page 4-24), remove the cables<br />

and screws (three M4 screws) connected to<br />

the motor control power supply board and<br />

remove the metal plate to which the motor<br />

control power supply board is attached.<br />

2) Remove the cables connected to the motor<br />

control power supply board, remove the screws<br />

(four M4 screws), and replace the motor control<br />

power supply board.<br />

Remove the<br />

three screws.<br />

3) After replacing the motor control power supply<br />

board, follow the disassembly procedure in the<br />

reverse order.<br />

Do not forget to tighten the screws and connect the<br />

cables.<br />

[Check points]<br />

Remove the<br />

eight screws.<br />

1) Turn on the radar power supply. After the<br />

countdown is completed, start emission and check that the radar image appears without<br />

error. Check that you do not hear any unusual sound when the motor starts, rotates, and<br />

stops.<br />

4-30

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!