INDEX > 4.Replacement Procedure > 4.3 Scanner Unit NKE-2254 (<strong>JMA</strong>-5322-7/9/6HS)<br />

[Replacement procedure]<br />

1) Remove the cover on the right<br />

(starboard) side (see Section 4.3.1, page 4-<br />

24), remove the cables connected to the<br />

transmitter-receiver unit and the screws<br />

(three M5 screws) holding the<br />

transmitter-receiver unit in place, and<br />

remove the transmitter-receiver unit.<br />

Remove the<br />

five cables.<br />

Remove the<br />

three screws.<br />

4<br />

2) Loosen the screws (nine M4 screws)<br />

holding the cover in place, remove the<br />

screws (two M4 screws) holding the heat<br />

radiation plate in place, and remove the<br />

cover.<br />

Loosen the<br />

nine screws.<br />

Remove the<br />

two screws.<br />

3) Remove the magnetron(see Section<br />

4.3.2, page 4-26).<br />

4) Remove the cables connected to the<br />

modulator circuit board, then remove<br />

the screws (two M4 screws) holding<br />

the waveguide.<br />

Remove<br />

4-33