09.03.2016 Views

JMA-5300MkIIsm

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

INDEX > 4.Replacement Procedure > 4.3 Scanner Unit NKE-2254 (<strong>JMA</strong>-5322-7/9/6HS)<br />

5) Remove the screws (M4) holding the<br />

Modulator unit to replace the<br />

Modulator unit. (Three screws in the<br />

back)<br />

Remove<br />

6) After replacing the<br />

Modulator unit, assemble the<br />

magnetron on to the new<br />

Modulator unit.<br />

7) Assemble the Modulator unit<br />

in the reverse order of the<br />

disassembly procedure.<br />

Do not forget to tighten the bolts<br />

and screws, and do not forget to<br />

reconnect the cables.<br />

Magnetron<br />

[Check points]<br />

1) Turn on the radar power supply. After the countdown is completed, start emission and<br />

check that the radar image appears without error.<br />

Transmit radar signals on a long range (48NM) and with the test menu open, also make sure<br />

the magnetron current is shown between the 6th and 9th calibration markings (see Section<br />

6.1.1, page 6-1).<br />

4-34