Focus on the Sustainability of Activities and their<br />
Impact on the Planet<br />
Research, Development and Innovation of Business Units and<br />
Eco-friendly Solutions<br />
Transformers<br />
The Transformers Unit invested in the systematic improvement of the<br />
<strong>de</strong>sign and manufacturing processes of its products. In <strong>2010</strong>, several<br />
projects were carried out with an impact on costs and quality:<br />
• Changes in the calculation methods of shunts.<br />
• Development of tools to calculate losses and temperatures in<br />
metallic parts exposed to magnetic fi elds and in shunts.<br />
• Tap changing automation.<br />
• Update of the calculation of short circuit stresses.<br />
• Integration of other programs in the Wintree.<br />
• Automatic dimensioning of Core-type windings in coils.<br />
• Development of thermal mo<strong>de</strong>ls in Shell-type transformers.<br />
• Changes in the databases to improve production interfaces.<br />
In <strong>2010</strong>, <strong>Efacec</strong> completed its fi rst study in the Assessment of the<br />
Life Cycle of a product. This is a methodology <strong>de</strong>veloped to assess<br />
the environmental aspects and impacts of the product throughout<br />
its whole life cycle. This inclu<strong>de</strong>s the product’s full and systematic<br />
study, from the extraction of raw materials and use of natural<br />
resources, to production, transport, use and fi nal <strong>de</strong>stination.<br />
The product selected for this fi rst study was the mineral oil-fi lled<br />
distribution transformer with 630 KVA UN 15000/ 420V, Dyn 5. With<br />
this study, it was possible to i<strong>de</strong>ntify the most environmentally<br />
critical phases of the industrial process, quantify resulting effl uents<br />
and supply additional information to the Customers.<br />
<strong>Efacec</strong> Power Transformer<br />
70<br />
Medium Voltage Switchgear<br />
Being the result of increasing international activities, in <strong>2010</strong> the<br />
Unit had a year particularly full regarding the testing of its various<br />
ranges of products.<br />
Therefore, in <strong>2010</strong> the <strong>Efacec</strong> Fluofi x GC.T product was acknowledged<br />
and approved by ENA (Energy Networks Association) to be used in the<br />
power distribution grid of the United Kingdom.<br />
Besi<strong>de</strong>s the British market, this product is aimed for other markets<br />
such as India, where the product began to be sold. This Ring Main<br />
Unit is used to protect the transformer in substations.<br />
The acquisition of a company for manufacturing substations in Spain<br />
(<strong>Efacec</strong> Equipos Eléctricos) fi ts with the strong investment ma<strong>de</strong><br />
in certifi cation tests in keeping with the requirements of the main<br />
Spanish power distribution companies, such as Iberdrola and En<strong>de</strong>sa,<br />
besi<strong>de</strong>s the AENOR certifi cation.<br />
The product of highlight in this market is the Fluofi x range, namely<br />
the 36 kV version.<br />
Likewise, the same was ma<strong>de</strong> for the certifi cation of products for<br />
Eastern markets, namely the assessment of the level of safety of the<br />
internal arc insi<strong>de</strong> substations, in accordance with the criteria of<br />
international standards. As such, the new range of modular Normafi x<br />
products had its performance increased to 20 kA.<br />
Also, in <strong>2010</strong> was conclu<strong>de</strong>d the certifi cation of the fi rst product<br />
from the Unit inten<strong>de</strong>d for the USA market with the testing ma<strong>de</strong><br />
to the IATS disconnector. Tests were ma<strong>de</strong> in accordance with ANSI/<br />
IEEE standards and successfully completed at the subsidiary of the<br />
KEMA lab, located in the USA.<br />
As for high voltage, in <strong>2010</strong> were ma<strong>de</strong> and tested the new versions<br />
of the SHD disconnector of center break at 245 kV and the new<br />
STE grounding disconnector at 550 kV, both inten<strong>de</strong>d to European<br />
markets or Latin America.<br />
Also enrolled in RDI activities, the expansion phase of the<br />
Empowerment project implemented by this Unit continued in <strong>2010</strong>,<br />
as well as process innovation and Lean Manufacturing projects and<br />
certifi cation of Processes implemented in <strong>Efacec</strong> Argentina.