Field Application Reports<br />

Products:<br />

Application Date:<br />

Customer:<br />

Industry:<br />

Location 15<br />

Rebuilding Motor Pads<br />

Deep Pour Grout<br />

March 1998<br />

Baltimore Gas & Electric<br />

Power Plant<br />

Problem:<br />

A centrifugal water pump pad was badly eroded <strong>and</strong> the pump plate became very loose. Severe vibration<br />

occurred <strong>and</strong> the anchor bolts became loose in the concrete. Over a period of time “chunks” of concrete<br />

broke away causing the plate to become very sloppy.<br />

Solution:<br />

The loose concrete was removed using a surface grinder. All loose particles were blown away with high<br />

pressure air. The surface was then cleaned with a degreaser to remove all oil <strong>and</strong> grease. Fir strips were<br />

used to “dam” the edges of the pump pad. The pump base plate was balanced on the concrete surface.<br />

Then Deep Pour Grout was poured onto the pad <strong>and</strong> allowed to “self level”. After 16 hours the plate was<br />

secure in the epoxy <strong>and</strong> ready for the pump to be re-connected.