Field Application Reports<br />
Products:<br />
Application Date:<br />
Customer:<br />
Industry:<br />
Location 38<br />
Centrifuge Chute <strong>Repair</strong><br />
Flexane® 80 Putty<br />
2/1/93<br />
City Of Chicago<br />
Water Treatment<br />
Problem:<br />
The steel transition chutes of the centrifuge conveying system would receive extreme abrasive wear. The<br />
wear was caused by compressing 3-6% solid through to 28-35% solids. The wear was so severe that the<br />
wear plates required immediate replacement.<br />
Solution:<br />
The wear plates were s<strong>and</strong>blasted to a SSPC-SP5 white metal finish. Complete surface area was then<br />
chemically cleaned using Cleaner Blend 300. FL10 <strong>and</strong> FL20 Primers were applied <strong>and</strong> each allowed to<br />
cure or dry for 15 minutes. Using both primers will improve adhesion of Flexane 80 Putty from 25 pli. To<br />
50 pli. Flexane 80 Putty was applied to a thickness ranging from 1/2” to 5”. Flexane 80 Putty provided a<br />
long lasting, abrasion resistant, <strong>and</strong> compression resistant protective lining.