Field Application Reports<br />

Products:<br />

Application Date:<br />

Customer:<br />

Industry:<br />

Location 38<br />

Centrifuge Chute <strong>Repair</strong><br />

Flexane® 80 Putty<br />

2/1/93<br />

City Of Chicago<br />

Water Treatment<br />

Problem:<br />

The steel transition chutes of the centrifuge conveying system would receive extreme abrasive wear. The<br />

wear was caused by compressing 3-6% solid through to 28-35% solids. The wear was so severe that the<br />

wear plates required immediate replacement.<br />

Solution:<br />

The wear plates were s<strong>and</strong>blasted to a SSPC-SP5 white metal finish. Complete surface area was then<br />

chemically cleaned using Cleaner Blend 300. FL10 <strong>and</strong> FL20 Primers were applied <strong>and</strong> each allowed to<br />

cure or dry for 15 minutes. Using both primers will improve adhesion of Flexane 80 Putty from 25 pli. To<br />

50 pli. Flexane 80 Putty was applied to a thickness ranging from 1/2” to 5”. Flexane 80 Putty provided a<br />

long lasting, abrasion resistant, <strong>and</strong> compression resistant protective lining.