Field Application Reports<br />

Products:<br />

Application Date:<br />

Customer:<br />

Industry:<br />

Location 47<br />

Expansion Joint <strong>Repair</strong><br />

Flexane® 80 Liquid<br />

4/3/95<br />

Barrick Mercur Mine<br />

Mining<br />

Problem:<br />

Cement based products used in the past to seal around chemical storage tanks continued to crack <strong>and</strong> fail.<br />

A seal needed to to be maintained to eliminate chemicals from seeping <strong>and</strong> contaminating the<br />

underground. The seal needed to resist chemicals such as Cyanide <strong>and</strong> remain flexible to withst<strong>and</strong><br />

thermal cycling (cold winters <strong>and</strong> warm summers).<br />

Solution:<br />

<strong>Repair</strong> areas were hydroblasted to remove loose concrete <strong>and</strong> clean contaminates. Cracks <strong>and</strong> joints were<br />

filled using a polypropylene backer. This prevented the Flexane 80 Liquid from migrating deep into the<br />

concrete. Crack <strong>and</strong> joint surfaces were then primed with FL20 Primer. FL20 Primer was allowed to cure<br />

or dry for 15 minutes. Flexane 80 Liquid was mixed <strong>and</strong> transferred into dish soap bottles for ease in<br />

dispensing. Following 4 months of service, no failures were visible.