SUPER SILT FENCE (SUPER FILTER FABRIC FENCE) - <strong>Sediment</strong> Removal Efficiency: LOW.<br />

This device is not an ABACT for special protection watersheds. However, it may be used with<br />

another BMP that is an ABACT (e.g. vegetated filter strip) to make it more effective. Super silt<br />

fence may be used to control runoff from some small disturbed areas where the maximum slope<br />

lengths for reinforced silt fence cannot be met <strong>and</strong> sufficient room for construction of sediment traps or<br />

basins does not exist.<br />

PA DEP<br />

Only those fabric types specified for use as silt fence by the manufacturer should be used.<br />

The maximum slope length — in both existing <strong>and</strong> final grade — above any super silt fence should not<br />

exceed that shown in Table 4.4 or Figure 4.3. The slope length shown is the distance from the fence to<br />

the drainage divide or the nearest upslope channel. NOTE: Slope length is not increased by use of<br />

multiple rows of super silt fence.<br />

Super silt fence should not be used in areas where rock or rocky soils prevent the full <strong>and</strong> uniform<br />

anchoring of the fence or proper installation of the fence posts. It should be used only where access<br />

exists or can be made for the construction equipment required to install <strong>and</strong> remove the chain link<br />

fencing (e.g. trencher <strong>and</strong> posthole drill).<br />

Super silt fence should be installed at level grade. Both ends of each fence section should be extended<br />

at least 8 feet upslope at 45 degrees to the main fence alignment to allow for pooling of water (see<br />

Figure 4.1).<br />

Super silt fence should be installed according to the details shown in St<strong>and</strong>ard Construction<br />

Detail # 4-10.<br />

An 8” deep trench should be excavated, minimizing the disturbance on the downslope side. The<br />

bottom of the trench should be at level grade.<br />

363-2134-008 / March 31, 2012 / Page 82