Glossary<br />

Configuration<br />

Connecting to common potential<br />

Device names<br />

Diagnostics<br />

Direct starter<br />

The systematic arrangement of the different <strong>ET</strong> <strong>200S</strong> modules (setup).<br />

The opening of a new voltage group by a power module. This enables individual connection<br />

of the sensor and load supply to common potential.<br />

Before an IO device can be addressed by an IO controller, it must have a device name. This<br />

procedure was selected for PROFIN<strong>ET</strong> because names are easier to handle than complex<br />

IP addresses.<br />

Assignment of a device name for a concrete IO device can be compared with the setting of<br />

the PROFIBUS address for a DP slave.<br />

An IO device does not have a device name upon delivery. An IO device can only be<br />

addressed by an IO controller - i.e., for transferring configuration data (including the IP<br />

address) during startup or for user data exchange during cyclic operation - after it has been<br />

assigned a device name with the programming device/PC.<br />

Diagnostics involves the identification, localization, classification, display, and further<br />

evaluation of errors, faults, and messages.<br />

Diagnostics provides monitoring functions that run automatically while the system is in<br />

operation. This increases the availability of systems by reducing setup times and downtimes.<br />

A direct starter is a → motor starter that switches a motor on and off directly. It consists of a<br />

circuit breaker and a contactor.<br />

<strong>Distributed</strong> IO systems<br />

are input/output units which are not deployed in the central device, but which are set up<br />

decentrally at a greater distance from the CPU, e. g.:<br />

• <strong>ET</strong> 200M, <strong>ET</strong> 200X, <strong>ET</strong> 200L, <strong>ET</strong> <strong>200S</strong><br />

• DP/AS-I Link<br />

• Other DP slaves either from Siemens or other manufacturers<br />

The distributed IO systems are connected to the DP master by means of PROFIBUS DP.<br />

DP master<br />

A→ master that acts in compliance with the IEC 61784-1:2002 Ed1 CP 3/1 standard is<br />

termed<br />

DP master.<br />

<strong>ET</strong> <strong>200S</strong><br />

Glossary-2 Manual, 12/2005, A5E00514527-03