01.06.2013 Views

Distributed I/O System ET 200S

Distributed I/O System ET 200S

Distributed I/O System ET 200S

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

New Information About the "<strong>ET</strong> <strong>200S</strong> <strong>Distributed</strong> I/O <strong>System</strong> Manual"<br />

3.2 Parameters for Analog Electronic Modules 2AO U ST, 2AO U High Feature and 2AO I ST, 2AO I High<br />

Feature<br />

3.2 Parameters for Analog Electronic Modules 2AO U ST, 2AO U High<br />

Feature and 2AO I ST, 2AO I High Feature<br />

4.5.6 Parameters for Analog Electronic Modules 2AO U ST, 2AO U High Feature and 2AO I ST, 2AO<br />

I High Feature<br />

Table 3-2 Parameters for analog output modules U, I<br />

2AO U ST, 2AO I ST,<br />

2AO U High 2AO I High<br />

Feature<br />

Feature<br />

Group diagnostics (parameter<br />

assignment error, internal error)<br />

Behavior in event of CPU/master<br />

STOP<br />

Diagnostics:<br />

Short-circuit to<br />

M 1<br />

• Disable<br />

• Enable<br />

• No output current and voltage<br />

• Switch substitution value<br />

• Keep last value<br />

--- • Disable<br />

• Enable<br />

Value range Default setting Range of efficiency<br />

Disable Module<br />

No output current and<br />

voltage<br />

Module<br />

Disable Channel<br />

--- Diagnostics:<br />

Wire break1 • Disable<br />

Disable Channel<br />

• Enable<br />

Type/range of --- • De-activated<br />

± 10 V Channel<br />

output<br />

• 1 V to 5 V<br />

• ± 5V<br />

• ± 10 V<br />

--- Type/range of • De-activated<br />

4 mA to 20 mA Channel<br />

output<br />

• 4 mA to 20 mA<br />

• ± 20 mA<br />

Substitute value 2 To 65535 (value range must be ± 10 V: 0 V<br />

Channel<br />

within the nominal range)<br />

± 20 mA: 0 mA<br />

4 mA to 20 mA: 4 mA<br />

1 V to 5 V: 1 V<br />

1 No diagnostics recognition between -0.296 V and +0.296 V or -1.1852 mA and +1.1852 mA<br />

2 If there is no voltage going to the interface module or COMPACT module but the supply to the analog output modules<br />

continues, the substitute values that have been assigned parameters are output. Substitute values must lie within the<br />

nominal range. You can assign values from -27648 to +27648 as parameters (in the case of parameter assignment by<br />

means of the device database (GSD) file).<br />

<strong>ET</strong> <strong>200S</strong><br />

3-2 Product Information, 12/2006, A5E00743001-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!