13.2.5 Inverter Characteristic Curve dialog<br />

The conversion efficiency is the relationship of the power output to the power input,<br />

dependent on the inverter power at that time.<br />

The specification of the efficiency given in manufacturers’ data sheets relates to the<br />

nominal output (power rating), which PV systems, however, are not able to deliver at most<br />

times of the year. Therefore the part load operation is much more important for the<br />

simulation results.<br />

The programme requires 7 support points to define the characteristic curve, ie the<br />

efficiency at 0, 5, 10, 20, 30, 50 and 100% of the nominal output.<br />

To view the characteristic curve in graphic form, click on the Graph button.<br />

For grid connected systems, the European efficiency support points are fixed and<br />

displayed. If changes are made, these are first calculated on exiting the entry field.<br />

-> See also:<br />

Database: Inverter<br />