9.4.3 Individual Appliance: Light<br />

Page Consumption > Individual Appliances: Selection > Definition of Electrical Appliances by<br />

Individual Appliances > Individual Appliances<br />

An appliance is defined as a light when it is switched on depending on the amount of<br />

daylight.<br />

Output: Electricity requirement in [kWh]<br />

Stand-by Input: an entry here is only made for appliances with this facility where stand-by<br />

is always active when the appliance is not in operation.<br />

Operating Times:<br />

All days the same: if the tick is removed, it is possible to enter different operating times<br />

for all the days of the week.<br />

Clock: The hours of operation are set by clicking on the fields (green field = in operation,<br />

white field = not in operation). The appliance can only operate within the defined<br />

operating hours.<br />

No Other Restriction: the operating times are as defined by the clock.<br />

Full Darkness: the operating hours are only valid if, at the same time, global radiation<br />

equals zero. .<br />

Dusk: the operating hours are only valid if, at the same time, global radiation is less than<br />

20 W/m².<br />

Dull Weather: the operating hours are only valid if, at the same time, global radiation is<br />

less than 50 W/m².<br />