10.1.2.2 PV array, stand-alone<br />
System > Technical data > PV array<br />
Stand-alone PV arrays require some different data to grid connected ones.<br />
-> How to proceed:<br />
1. Give the array a Name.<br />
2. Select a PV module.<br />
If your desired module is not available, you must first enter it in the PV module database.<br />
Leave the Load file dialog by clicking OK. The parameters are taken over into the current<br />
project.<br />
The complete data record of the selected modules appears in an information window if the<br />
cursor is held over the PV modules button.<br />
3. As required, select the option Create preview of roof layout with Photo Plan.<br />
4. Enter the Installation type: free, with rear ventilation or without rear ventilation.<br />
5. Array output:<br />
- Specify the number of modules: Enter the Number of modules.<br />
- Determine output from roof area: The Minimum distance of the rows of modules<br />
are calculated in the Roof parameters dialog in order to minimize mutual shading<br />
and thus determine the number of modules from the available roof area.<br />
The resulting output of the array is calculated from the number of modules.<br />
6. Orientation<br />
With the help of the Orientation, the irradiation onto the horizontal surface is<br />
converted into irradiation to the inclined PV area.<br />
For stand-alone systems only:<br />
The DC cabling to the charge controller is the cabling from the string distributor of the PV<br />
modules to the charge controller. Standard Cable cross sections are available in the<br />
selection drop-down box; it is possible to enter other cross sections.<br />
The cabling losses in the cables of the individual modules to the string distributor can be<br />
generally taken into account in the "Calculation model and losses" dialog.<br />
If several cables run in parallel to the charge controller, please add together the cable<br />
cross sections of the individual cables.<br />