10.1.3.2 PV array, grid connected<br />
System > Technical data > PV array<br />
The PV array is specified on this page.<br />
-> How to proceed:<br />
1. Give the array a Name.<br />
2. Select a PV module.<br />
If your desired module is not available, you must first enter it in the PV module database.<br />
Leave the Load file dialog by clicking OK. The parameters are taken over into the current<br />
project.<br />
The complete data record of the selected modules appears in an information window if the<br />
cursor is held over the PV modules button.<br />
3. As required, select the option Create preview of roof layout with Photo Plan.<br />
4. Enter the Installation type: free, with rear ventilation and without rear ventilation.<br />
5. Array output:<br />
- Specify the number of modules: Enter the Number of modules.<br />
- Determine output from roof area: The Minimum distance of the rows of modules<br />
are calculated in the Roof parameters dialog in order to minimize mutual shading<br />
and thus determine the number of modules from the available roof area.<br />
The resulting output of the array is calculated from the number of modules.<br />
6. Orientation<br />
With the help of the Orientation, the irradiation onto the horizontal surface is<br />
converted into irradiation to the inclined PV area.<br />
7. Inverter<br />
Load an Inverter.<br />
The name of the inverter appears on the right. The complete data record of the selected<br />
inverter appears in an information window if the cursor is held over the Inverter button.<br />
! The Inverter button and the Number of inverters input field cannot be seen under System<br />
inverter. These entries are made on the System inverter page.<br />
o If the option "Set fixed number of modules in series when selecting<br />
inverter" is selected, only those inverters which fit in series for the given<br />
number of modules are displayed.<br />
o If the option "Set fixed number of modules in series when selecting<br />
inverter" is not selected, all inverters which fit in any configuration are<br />
displayed. After selecting the inverter, a suitable configuration can be<br />
selected for the number of modules in series in Configuration .<br />
8. Enter the Number of inverters.<br />
The installed inverter output and the MPP tracking range are displayed.<br />
9. Configuration per Inverter<br />
75