Definitions<br />
External Temperature<br />
The external temperature is a specification taken from the climate data files. It is required<br />
to define the module temperature, as the module efficiency is dependent on the<br />
temperature (see PV Module).<br />
Generated Solar Energy (Alternating Current Side)<br />
The generated solar energy (AC side) is the energy after conversion of the PV direct current<br />
into alternating current, which can either be fed into the grid or used to cover the load<br />
requirement. The energy used by the inverter itself is not taken into account.<br />
Generated Solar Energy (Direct Current Side)<br />
When designing a PV system, the energy that is produced by the PV modules is also of<br />
interest, ie the energy flow before entry into inverter.<br />
Grid, Electricity From<br />
If all the energy produced by the PV system is fed into the grid, the total load requirement<br />
and the inverter’s own consumption will have to be covered by electricity drawn from the<br />
grid. If the ”Own Use” concept is selected, the energy drawn from the grid is reduced by<br />
the proportion of PV generated energy that is used to cover the load requirement.<br />
Grid, Electricity To<br />
If the ”Full Supply” to grid concept is selected (see Tariffs), all solar energy generated is<br />
fed into the grid and this dimension is not given. If the ”Own Use” concept is selected,<br />
only the proportion of energy that is not used by the appliances is exported to the grid.<br />
Inverter Efficiency<br />
The inverter efficiency is the energy generated on the alternating current side in relation to<br />
the energy fed into the direct current side.<br />
The efficiency is made up of the Inverter Characteristic Curve, the MPP adjustment<br />
efficiencies (see Inverter Database) and the inverter’s own consumption.<br />
A very poor inverter efficiency (in comparison to maximum efficiency) is above all possible<br />
if the inverter is oversized or because its maximum nominal output limits the PV power<br />
output.<br />
Irradiation onto Tilted Array Surface<br />
The irradiation onto the tilted Array surface is the energy (after subtraction of shade) on<br />
the PV surface that is available for conversion. A proportion of this energy is lost through<br />
reflection on the module’s surface.<br />
Module Temperature<br />
There are two different Temperature Models in the programme. Module temperature<br />
definition is dependent on the climate data, module specific parameters and the type of<br />
mount. The module temperature for each array is given on each array worksheet.<br />
207