Definitions<br />

External Temperature<br />

The external temperature is a specification taken from the climate data files. It is required<br />

to define the module temperature, as the module efficiency is dependent on the<br />

temperature (see PV Module).<br />

Generated Solar Energy (Alternating Current Side)<br />

The generated solar energy (AC side) is the energy after conversion of the PV direct current<br />

into alternating current, which can either be fed into the grid or used to cover the load<br />

requirement. The energy used by the inverter itself is not taken into account.<br />

Generated Solar Energy (Direct Current Side)<br />

When designing a PV system, the energy that is produced by the PV modules is also of<br />

interest, ie the energy flow before entry into inverter.<br />

Grid, Electricity From<br />

If all the energy produced by the PV system is fed into the grid, the total load requirement<br />

and the inverter’s own consumption will have to be covered by electricity drawn from the<br />

grid. If the ”Own Use” concept is selected, the energy drawn from the grid is reduced by<br />

the proportion of PV generated energy that is used to cover the load requirement.<br />

Grid, Electricity To<br />

If the ”Full Supply” to grid concept is selected (see Tariffs), all solar energy generated is<br />

fed into the grid and this dimension is not given. If the ”Own Use” concept is selected,<br />

only the proportion of energy that is not used by the appliances is exported to the grid.<br />

Inverter Efficiency<br />

The inverter efficiency is the energy generated on the alternating current side in relation to<br />

the energy fed into the direct current side.<br />

The efficiency is made up of the Inverter Characteristic Curve, the MPP adjustment<br />

efficiencies (see Inverter Database) and the inverter’s own consumption.<br />

A very poor inverter efficiency (in comparison to maximum efficiency) is above all possible<br />

if the inverter is oversized or because its maximum nominal output limits the PV power<br />

output.<br />

Irradiation onto Tilted Array Surface<br />

The irradiation onto the tilted Array surface is the energy (after subtraction of shade) on<br />

the PV surface that is available for conversion. A proportion of this energy is lost through<br />

reflection on the module’s surface.<br />

Module Temperature<br />

There are two different Temperature Models in the programme. Module temperature<br />

definition is dependent on the climate data, module specific parameters and the type of<br />

mount. The module temperature for each array is given on each array worksheet.<br />

207