7.2.2 Quick design of grid-connected systems<br />
In the quick design, the system consists of one array and can have several inverters. The<br />
energy generated is fed into the grid in full and an appliance is not defined.<br />
Using the system output and after selecting module and inverter types, a recommendation<br />
for the number of configuration of the modules and the number of inverters is calculated.<br />
-> How to proceed:<br />
1. Start the quick design via File > New project > "Start new project with quick design" > OK<br />
2. Enter a project name.<br />
3. Click on Climate data to set a location.<br />
4. Click on PV module to select a PV module from the database.<br />
5. Enter the Azimuth and the Inclination of the PV modules.<br />
6. Enter either the Desired system output OR a Set number of modules.<br />
7. Accordingly, click either on Inverter to select one from the database, or on Inverter<br />
combinations. Inverter combinations - configuration selection<br />
7.1 The configuration selection starts with the message "<br />
A suitable configuration could not be found",<br />
until you have selected a suitable inverter; then it starts with the last selected<br />
inverter.<br />
Confirm by clicking OK.<br />
7.2 Select either a) Select inverter manufacturer or b) Select inverter model.<br />
7.3a) Select the desired Manufacturer from the list. In the window to the right, all<br />
suitable inverters from this manufacturer are shown.<br />
Set the Number of different configurations and inverter types.<br />
7.3b) In the Inverter data area, click on New or Other inverter model to select an<br />
inverter with the help of filters.<br />
The inverter database with the following filters appears:<br />
- Manufacturer<br />
- Matching default data<br />
- In threshold range<br />
- Not matching<br />
- Filter according to permissible unbalanced load<br />
- Show only user-created data records<br />
- Show products that are not available<br />
Here, you can also import or export inverter data records.<br />
7.4 As required, you can select the following configuration criteria:<br />
- Allow wider tolerances (+/- 20%) when checking the sizing factors.<br />
- Show all possible configurations<br />
- Filter according to permissible unbalanced load (in relation to total system)<br />
7.5 Possible configurations are shown in the Select module/inverter configuration<br />
table. Choose one and then leave the dialog by clicking OK.<br />