10.1.5 Installation Type<br />

System > Technical Data > PV Array / Array i > Installation Type<br />

The installation type influences the heating of the PV modules.<br />

With a ”Free-Standing” mount the entire module surface (front and back) exchanges<br />

radiation with its environment.<br />

For a roof-top mount ”With Ventilation” only the upper module surface is available for<br />

radiation exchange, and for roof-top or façade integration ”Without Ventilation” this is<br />

reduced further. With roof or building integration the output is reduced further by a lack of<br />

convection.<br />

High module temperature leads to a drop in module efficiency. Yields for PV systems with<br />

free-standing mounting are therefore higher than those for systems with ventilation space<br />

which in turn have higher yields than systems without ventilation space.<br />