Table F-5 Pilot Scale Study on Ammonia Stripping wi<strong>th</strong> Varying Cont<strong>ac</strong>t Time (Re<strong>ac</strong>tor<br />

Volume 40 L, pH 11-12, Velocity Gradient 2,850 s -1 )<br />

Initial<br />

Cont<strong>ac</strong>t Time<br />

Concentration 1 h 2 h 3 h 4 h 5 h<br />

(mg/L) NH3 R NH3 R NH3 R NH3 R NH3 R<br />

(mg/L) (%) (mg/L) (%) (mg/L) (%) (mg/L) (%) (mg/L) (%)<br />

1,160 722 38 487 58 235 80 202 83 104 91<br />

1,473 902 22 675 42 375 68 266 77 140 88<br />

* R – Ammonia Removal Efficiency<br />

Table F-6 Verification <strong>of</strong> <strong>th</strong>e Optimum Parameters for <strong>th</strong>e Ammonia Stripping Studies<br />

wi<strong>th</strong> Varying Ammonia Concentration in <strong>th</strong>e Le<strong>ac</strong>hate (Velocity Gradient: 2,850 s -1 , pH:<br />

11-12, Cont<strong>ac</strong>t Time: 5 h)<br />

Sample No.<br />

Ammonia Concentration (mg/L)<br />

Initial Final<br />

Removal Efficiency (%)<br />

1 1,473 140 90<br />

2 1,546 148 91<br />

3 1,310 151 88<br />

4 1,753 218 88<br />

5 1,546 241 84<br />

6 1,414 227 84<br />

7 1,358 202 85<br />

8 1,277 210 84<br />

9 1,369 218 84<br />

10 1,442 238 83<br />

11 1,389 179 87<br />

12 1,490 162 89<br />

13 1,532 218 86<br />

14 1,473 140 90<br />

15 1,546 148 91<br />

Average 1,455 196 86<br />