Structural Health Monitoring Using Smart Sensors - ideals ...
Structural Health Monitoring Using Smart Sensors - ideals ...
Structural Health Monitoring Using Smart Sensors - ideals ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
1<br />
1<br />
Normalized accumulated stress<br />
measurement 3 measurement 2 measurement 1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
Normalized accumulated stress<br />
measurement 3 measurement 2 measurement 1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
0<br />
3 4 5 6 7 8 9 1011 7 8 9 10 111213 1415 1112 1314 151617 1819<br />
Element ID<br />
(a)<br />
3 4 5 6 7 8 9 1011 7 8 9 10 111213 1415 1112 1314 151617 1819<br />
Figure 8.14. Damage detection (damaged element: Element 9): (a) mass perturbation<br />
DLV; and (b) SDLV.<br />
0<br />
Element ID<br />
(b)<br />
1<br />
1<br />
Normalized accumulated stress<br />
measurement 3 measurement 2 measurement 1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
Normalized accumulated stress<br />
measurement 3 measurement 2 measurement 1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
0<br />
1<br />
0.5<br />
0.3<br />
0<br />
3 4 5 6 7 8 9 1011 7 8 9 10 111213 1415 1112 1314 151617 1819<br />
Element ID<br />
(a)<br />
0<br />
3 4 5 6 7 8 9 1011 7 8 9 101112131415 111213141516171819<br />
Element ID<br />
(b)<br />
Figure 8.15. Damage detection (damaged element: Element 10): (a) mass perturbation<br />
DLV; and (b) SDLV.<br />
From a theoretical perspective, false-negatives, on the other hand, are not expected if<br />
conditions such as linearity of the structure and no observation noise are satisfied. No<br />
false-negative damage detection is found in Bernal (2002) and Gao (2005). In the Imote2<br />
experiments, false-negatives are observed. For example, Figure 8.16 (a) shows the<br />
damage detection results when element 11 is replaced with the damaged element. Seven<br />
false-negative damage detection cases are observed in this figure. The SHM system<br />
cannot detect damage in this case, even though the three sensor communities commonly<br />
monitor the replaced element. Gao (2005) stated that detecting damage in the vertical and<br />
diagonal elements located close to the midspan of the truss structure was found to be more<br />
difficult than for other elements. Damage detection of elements carrying small force under<br />
self-weight is considered challenging. Small forces in vertical element 11 under self-<br />
151