MC 3000<br />
Operating Manual<br />
7 ADDITIONAL MESSAGES<br />
7.1 MALFUNCTION MESSAGES<br />
SYSTEM RESET !<br />
The MC-3000 has detected a serious malfunction in its electronic components. Contact<br />
an authorized <strong>Oberheim</strong> service centre as soon as possible.<br />
UART (DA 0 A 6): CHIP FAILURE !<br />
The control software has noted that a UART chip is not responding to the system. Since<br />
the UART chips control the MC-3000 serial ports (such as the MIDI OUT ports and the<br />
Mouse port), after this message is displayed some of them will not work. Contact an<br />
authorized service centre for a solution to the problem.<br />
KEYBOARD FAILED !<br />
During the self-testing procedure (which takes place whenever the instrument is switched<br />
on) the keyboard does not respond to the control messages. Contact an authorized<br />
service centre for a solution to the problem.<br />
7.2 ERROR MESSAGES<br />
IN (1,2): MIDI STATUS ERROR<br />
The error may appear in any operating mode (Program, Edit, Chain, Utility) and indicates<br />
that illegal MIDI data are present at the MC-3000 input ports. Check the instrument from<br />
which the data are originating and the connections made.<br />
PATCH (NUMBER, BANK) ERROR<br />
The memory location of the selected patch contains illegal data not recognized by the MC-<br />
3000 software. If the error persists, carry out a factory setting (reset) of the memory<br />
location concerned following the instructions in point 8.1 "Reset Procedure" (Factory<br />
settings).<br />