MC 3000<br />

Operating Manual<br />

8 ANNEX<br />

8.1 RESET PROCEDURES (FACTORY SETTINGS)<br />

The MC-3000 control software is extremely complex and its programming and optimization<br />

have been very demanding tasks.<br />

Every condition of use of the instrument has been analyzed, reproduced and verified, but<br />

we are unable to rule out the possibility that particular situations may occur in which the<br />

instrument is unable to operate correctly due to unpredictable external factors such as<br />

magnetic fields or serious mains power disturbances.<br />

For this reason, a number of special functions have been combined in a page which can<br />

only be accessed using a special procedure, to be carried out when the instrument is<br />

switched on.<br />

To access the reset procedure, first switch the MC-3000 off and back on, keeping the<br />

WRITE key pressed. The following video page will appear on the display:<br />

As the presence of the SECTION field indicates, the MC-3000 allows the user to perform<br />

a SELECTIVE RESET, meaning that the section and memory location to be initialized can<br />

be decided.<br />

The options available to the user in the section field are:<br />

• ALL: The whole of the instrument's internal memory undergoes a RESET (factory<br />

setting).<br />

• PROGRAMS: Program reset.<br />

• CHAIN: Reset of the data relating to the chains<br />

• PG TABLES: Reset of the data relating to the program change tables.<br />

• SYS TABLES: Reset of the data relating to the exclusive system tables<br />

• DYNAMIC CURVES: Reset of the data relating to the dynamic curves<br />

• AFTERTOUCH CURVES: Reset of the data relating to the Aftertouch curves.<br />

Caution: when one or more sections undergo a RESET all the user data they contain<br />

will be lost irremediably!<br />

The range of the memory locations to be initialized within the chosen section can be<br />

selected in the fields FROM and TO fields.<br />

Once the desired settings have been made, press function key F6 (RUN) to start the<br />

initialization procedure. When the procedure is complete the MC-3000 will repeat the<br />

switch-on procedure.<br />