Chapter 3: Troubleshooting<br />
Cannot Establish a Local (Out-of-Band) Management Session<br />
If you are unable to establish a local (out-of-band) management session<br />
with the switch through the terminal port on the front panel, do the<br />
following:<br />
<br />
<br />
<br />
<br />
Check to be sure that the RJ-45 serial management cable is securely<br />
connected to the serial terminal port on the switch and to the RS-232<br />
port on the terminal or personal computer.<br />
Check to be sure that the operating parameters on the terminal or the<br />
terminal emulation program, if you are using a personal computer,<br />
have been set correctly. The default settings for the RJ-45 serial<br />
terminal port are located in “Starting a Local Management Session” on<br />
page 93.<br />
Check to be sure that the terminal emulator application is compatible<br />
with a VT-100 terminal.<br />
Check to be sure that the configuration settings conform with those<br />
given in “Starting a Local Management Session” on page 93.<br />