SwitchBlade x3112 Installation Guide - Allied Telesis
SwitchBlade x3112 Installation Guide - Allied Telesis
SwitchBlade x3112 Installation Guide - Allied Telesis
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
<strong>SwitchBlade</strong> <strong>x3112</strong> <strong>Installation</strong> <strong>Guide</strong><br />
Installing the AT-SBx3161 System Power Supply<br />
The <strong>SwitchBlade</strong> <strong>x3112</strong> can host up to four power supplies consisting of<br />
two AT-SBx3161 System Power Supplies and two AT-SBx3165 PoE<br />
Power Supplies. The AT-SB<strong>x3112</strong> Chassis comes with three blank power<br />
supply panels in chassis slots A, B, and C as displayed in Figure 39. Slot<br />
D is left open for the installation of the first AT-SBx3161 System Power<br />
Supply. Keep the blank power supply panels in place on the unused slots<br />
to insure proper chassis airflow.<br />
AT-SBx3165 PoE Power Supply Slots<br />
A<br />
B<br />
AT-SBx3161 System Power Supply Slots<br />
C<br />
D<br />
P<br />
O<br />
E<br />
P<br />
O<br />
E<br />
S<br />
Y<br />
S<br />
T<br />
E<br />
M<br />
S<br />
Y<br />
S<br />
T<br />
E<br />
M<br />
SB 31FAN<br />
1891<br />
Figure 39. Slots A to D for System and PoE Power Supplies<br />
Note<br />
The label for the AT-SBx3161 System Power Supply model number<br />
is located on the right-hand side of the power supply handle as<br />
shown in Figure 20 on page 41. This power supply may be installed<br />
in one of the two power supply slots on the right-hand side of the<br />
chassis - slots C or D. See Figure 39 for the location of these slots.<br />
Warning<br />
The AT-SBx3161 System Power Supply contains active electronic<br />
devices, which can be damaged by electro-static discharges (ESD).<br />
Follow the procedure given in “Protection Against Electrostatic<br />
Discharge (ESD)” on page 64 to guard against ESD damage when<br />
unpacking and installing these power supplies.<br />
To install the AT-SBx3161 power supply, perform the following procedure:<br />
1. Choose a slot in the chassis for the AT-SBx3161 System Power<br />
Supply. You can install the system power supply in either of the two<br />
right-hand slots - slot C or D. (See Figure 39 for the location of these<br />
slots.) If this is the initial installation of the chassis, <strong>Allied</strong> <strong>Telesis</strong><br />
recommends slot D because it does not have a blank power supply<br />
panel installed.<br />
65