Chapter 3: Troubleshooting<br />
AT-SBx31CFC Fabric Control Card SBx Status LEDs Flashing Amber<br />
If a SBx Status LED is flashing amber, the line card has experienced a<br />
FAULT or an error condition. See “SBx STATUS LED Description on the<br />
Active AT-SBx31CFC Fabric Control Card” on page 23 for an explanation<br />
of all status conditions.<br />
Note<br />
All line cards are hot swappable. This allows the AC power to be<br />
connected to the <strong>SwitchBlade</strong> <strong>x3112</strong> while you re-seat or exchange<br />
line cards.<br />
<br />
If a FAULT condition is encountered for one of the card slots, you can<br />
attempt to restart the line card. The following example is for restarting<br />
a card in slot 2:<br />
officer SEC>> restart card 2<br />
You will be prompted as follows - enter y for YES:<br />
Do you really want to restart card 2 (Y/N)? y<br />
Command has been submitted<br />
officer SEC>><br />
<br />
<br />
If the RESTART CARD command is not successful, remove the line<br />
card from the slot and re-seat until the face plate is flush with the<br />
chassis front panel. Wait for 2 to 3 minutes for it to come on line. If it<br />
successfully comes up, the SBx Status LED for the slot in question<br />
turns to solid green.<br />
You can obtain specific card status information for each card slot<br />
through the Switchblade <strong>x3112</strong> Management Software by entering the<br />
SHOW CARD command as follows:<br />
officer SEC>> show card<br />
<br />
If the SBx Status LED for the slot continues to flash amber after the<br />
above actions have been taken, contact <strong>Allied</strong> <strong>Telesis</strong> for further<br />
assistance. Please report the slot where the SBx Status LED fault<br />
condition is present and the information obtained from the SHOW<br />
CARD command.<br />