Chapter 3: Troubleshooting<br />
AT-SBx31CFC Fabric Control Card PSU Fault LED Flashing Amber<br />
Check the PSU System Status LED on the front of the AT-SBx31CFC card<br />
for a solid green or flashing amber status. A flashing amber status LED<br />
indicates a FAULT condition on one or more power supplies.<br />
Check each Fault LED on each AT-SBx3161 System Power Supply and<br />
AT-SBx3165 PoE Power Supply to see which one(s) is solid amber and<br />
then do the following:<br />
<br />
You can obtain the current status for each power supply by using the<br />
Switchblade <strong>x3112</strong> Management Software by entering the following<br />
commands:<br />
officer SEC>> SHOW PSU<br />
officer SEC>> SHOW PSU FULL<br />
Contact <strong>Allied</strong> <strong>Telesis</strong> Technical Support for further assistance. Please<br />
report the power supply fault condition and the information obtained<br />
from the SHOW PSU and SHOW PSU FULL commands.<br />
<br />
If the affected power supply needs to be replaced, remove it and install<br />
a replacement power supply. Refer to “Installing the AT-SBx3161<br />
System Power Supply” on page 65.<br />
Note<br />
The AT-SBx3161 System Power Supply and AT-SBx3165 PoE<br />
Power Supply are hot swappable when used in a redundant<br />
configuration. This allows the <strong>SwitchBlade</strong> <strong>x3112</strong> to continue to<br />
operate while you exchange power supplies.<br />
96