RS-232 Upload/Download<br />
The format for a parameter upload response will consist of 192 bytes plus the bcc and eot<br />
characters:<br />
(Mark Parity)<br />
The bcc is calculated by performing the XOR function on the 192 bytes of packet data.<br />
A complete parameter upload will consist of the PC requesting four parameter packets<br />
(30h - 33h) from the Accu-Setter. The PC must wait for the parameter response packet<br />
before requesting the next parameter packet.<br />
Example of a complete parameter upload for station #0:<br />
Successful Upload for Parameter Packet 0<br />
PC -> Accu-Setter <br />
PC Accu-Setter <br />
PC Accu-Setter <br />
PC Accu-Setter <br />
PC