3.2 Signal <strong>Co</strong>nditioning Module Setup<br />
For LVDT modules E9310 & E9320 attenuation jumpers must be set to either 1x for<br />
standard transducers or 10x for long range transducers. Refer to the "Advanced<br />
Operations" section for additional information.<br />
For either an LVDT or A/E signal conditioning module a jumper matrix on the board<br />
allows it to accept signals in or send signals out to the analog output connector. Refer to the<br />
"Advanced Operations" section of the manual for additional information on setting these<br />
jumpers.<br />
Signal <strong>Co</strong>nditioning Module Auto Recognition<br />
When an E9310, E9320, E9330, or E9340 module is installed in the lower bay the<br />
<strong>Accusetter</strong> II will automatically detect the type of signal conditioning module installed and<br />
certain setup parameters will be programmed automatically based on the jumper settings on<br />
the module. This feature is not available on legacy signal conditioning modules.<br />
For an E9310 or E9320 module the following parameters will be detected:<br />
• Under the "Xducer" menu the Signal <strong>Co</strong>nditioning will be set to "Electric"<br />
• The position of the attenuation jumpers J5-J8 and J10 (1x or 10X) will be detected<br />
For an E9330 or E9340 module the following parameters will be detected:<br />
• Under the "Xducer" menu the Signal <strong>Co</strong>nditioning will be set to "Air"<br />
When the <strong>Accusetter</strong> II is powered on the module ID code of the currently installed module<br />
is displayed in the scroll of start up information. For the LVDT modules E9310 & E9320<br />
the ID code will also identify the status of the "J10" attenuation jumper (1x or 10x).<br />
Module<br />
ID <strong>Co</strong>de<br />
E9010, 20, 30, 40 Legacy Module<br />
FF<br />
(no module recognition)<br />
E9310, Jumper J10 = 1x E1<br />
E9310, Jumper J10 = 10x E2<br />
E9320, Jumper J10 = 1x E3<br />
E9320, Jumper J10 = 10x E4<br />
E9330<br />
E5<br />
E9340<br />
E6<br />
Power to the column must be turned off prior to installing or removing a signal<br />
conditioning module.<br />
3-6